HAC-60
Belimo LMB24-SR-T
Inline Damper
Proportional Blade Positioning · 24 Vac/dc · Holds Last Position · 6"–20"
3-wire floating point → HAC-34 (CMB24-3-T)
On/off 2-position → HAC-40 (TFB24)
What It Does
Proportional 2–10 VDC modulating control. No spring return — holds last position on power loss.
The HAC-60 pairs Hoyme's inline damper body with the Belimo LMB24-SR-T modulating actuator. Like the HAC-43 (TFB24-SR-T), the LMB24-SR-T accepts a 2–10 VDC analog signal and positions the damper blade proportionally across the full range of travel. The single practical difference: the LMB24-SR-T has no spring return. On power loss, the blade holds its current position rather than moving to a defined fail-safe open or closed state.
For most commercial BAS applications where the DDC controller manages blade position and resumes control after a power event, holds-last-position is the preferred behavior — it avoids abrupt airflow changes during brief power interruptions. Where a defined fail-safe position is required, use the HAC-43.
HAC-60 vs. HAC-43 — The One Decision That Matters
Both accept 2–10 VDC and provide proportional blade positioning. The only meaningful difference is how they behave on power loss.
| Spec | HAC-43 (TFB24-SR-T) | HAC-60 (LMB24-SR-T) — this product |
|---|---|---|
| Control Input | 2–10 VDC analog | 2–10 VDC analog |
| Proportional Range | Full blade travel | Full blade travel |
| Supply Voltage | 24 Vac/dc | 24 Vac/dc |
| On Power Loss | Spring return to fail-safe position (open or closed) | Holds last blade position — no movement |
| Heat Bypass (−H) | Not available | Available on all sizes |
| Choose When | Fail-safe position required on power loss | Holds-last-position is acceptable; lighter actuator suits the application |
Belimo Series — Control Type Selector
All Belimo-actuated HAC variants on a single Hoyme inline damper body. Select by control type and voltage.
| Model | Actuator | Control Type | Voltage | Spring Return | Link |
|---|---|---|---|---|---|
| HAC-40 | TFB24 | On/Off | 24 Vac/dc | Yes | View |
| HAC-44 | TFB120 | On/Off | 100–240 Vac | Yes | View |
| HAC-43 | TFB24-SR-T | Modulating 2–10 VDC | 24 Vac/dc | Yes | View |
| HAC-60 ← You are here | LMB24-SR-T | Modulating 2–10 VDC | 24 Vac/dc | No — holds last | — |
| HAC-34 | CMB24-3-T | Floating point 3-wire | 24 Vac/dc | No — holds last | View |
| HAC-30 | LMB24-3-T | Floating point 3-wire | 24 Vac/dc | No — holds last | View |
| HAC-35 | CMB120-3 | Floating point 3-wire | 100–230 Vac | No — holds last | View |
| HAC-70 | LMX120-3 | Floating point 3-wire | 100–230 Vac | No — holds last | View |
| HAC-90 | FSLF24 US | Fire & Smoke (UL 555S) | 24 Vac | Yes | View |
| HAC-80 | FSLF120 US | Fire & Smoke (UL 555S) | 120 Vac | Yes | View |
Configuration Guide
Select size, end switch (OPP or SPP), and heat bypass. Confirm PP action code signal direction with the DDC controls designer before ordering.
| Variant Code | End Switch | Heat Bypass | Part Number Example (10") |
|---|---|---|---|
| OPP | No end switch | No bypass | HAC-1060-OPP |
| OPP-H | No end switch | 10% bypass | HAC-1060-OPP-H |
| SPP | End switch included | No bypass | HAC-1060-SPP |
| SPP-H | End switch included | 10% bypass | HAC-1060-SPP-H |
Key Specs
Common Questions from the Counter
Answers to what comes up most when specifying the HAC-60.