Reference & Documentation

Technical Library

Installation instructions, colour wiring diagrams, troubleshooting guides, relay replacement procedures, product information sheets, and testing documentation for all Hoyme Manufacturing products. All documents open as PDF — plus short field videos from our technical support team.

Installation Guides

All products & configurations

Colour Wiring Diagrams

Inspector-ready, every ADP model

Product Spec Sheets

Dimensions, ratings & certs

Troubleshooting & Service

Relay replacement & conversion

Testing & Certification

CSA & NRC documentation

Watch & Learn

Video Learning Library

Short, practical videos on damper selection, wiring, and the field questions we hear most — from the same team that answers the technical support line. New episodes post every week on our YouTube channel.

HAC — Why New Builds Need a Motorized Damper

HOM — Why New Houses Starve Their Furnaces of Air

ADP — The One Part That Fails Inspections

More videos on the Hoyme Manufacturing YouTube channel — new episodes every Friday.

Section 1

Installation Instructions

Step-by-step installation and wiring instructions for all Hoyme motorized dampers and ADP interface relay adaptors. PDF documents cover residential and commercial applications across all product families.

HAC — Inline Motorized Air Control Dampers

HOM — Combustion Air Damper

MAC — Motorized Make-Up Air / Fresh Air Damper

HAE — Furnace Fan Generated Air Exchanger

ADP — Interface Relay Adaptors (All Models)

Installation instructions for all Hoyme ADP relay adaptor models. ADP adaptors interlock fresh air dampers, combustion air dampers, exhaust fans, and furnaces — available in 24Vac, 110Vac, 110/24Vac, and millivolt configurations.

ADP-0241-05A Installation Instructions
24Vac fresh air damper + furnace fan sequencing
PDF ↓
ADP-0240-1WS Installation Instructions
24Vac combustion air / furnace interlock
PDF ↓
ADP-0242-05A Installation Instructions
Humidifier / heating-cooling interlock
PDF ↓
ADP-0243-S5A Installation Instructions
24Vac adaptor
PDF ↓
ADP-0244-05A Installation Instructions
Two-zone furnace fan control — 24Vac
PDF ↓
ADP-024T-S20VA Installation Instructions
24Vac timer adaptor
PDF ↓
Grasslin Interval Timer Operation Instructions
Centre pin settings, 3-way override — TMADP & ADP-024T series
PDF ↓
ADP-0MV2-S5A Installation Instructions
Millivolt furnace — standing pilot / thermopile interlock
PDF ↓
ADP-1101-05A Installation Instructions
120Vac exhaust fan + fresh air damper interlock
PDF ↓
ADP-1101-10AS Installation Instructions
120Vac adaptor with switched output
PDF ↓
ADP-1101-10AV Installation Instructions
120Vac adaptor
PDF ↓
ADP-1102-10A Installation Instructions
110Vac boiler & oil burner interlock — 10A
PDF ↓
ADP-1102-S5A Installation Instructions
110Vac boiler & oil burner interlock — 5A
PDF ↓
ADP-1102-TPX Installation Instructions
End-switch proving adaptor
PDF ↓
ADP-1102-TW5 Installation Instructions
Two-wire 5-pin adaptor
PDF ↓
ADP-1102-TWP Installation Instructions
Two-wire parallel adaptor
PDF ↓
ADP-1103-TW5 Installation Instructions
Three-wire 5-pin adaptor
PDF ↓
ADP-1103-TPX Installation Instructions
Three-wire proving adaptor
PDF ↓
RADP-0241-10A Installation Instructions
Remote 24Vac adaptor with controlled receptacle
PDF ↓
RADP-0241-S10A Installation Instructions
Remote adaptor — gas dryer replacement air
PDF ↓
RADP-0242-S10A Installation Instructions
Remote adaptor — dual damper gas dryer
PDF ↓
RADP-1102-TPX Installation Instructions
Remote plug-in proving adaptor
PDF ↓
TMADP-1102-TPX Installation Instructions
Timer adaptor — timed ventilation sequences
PDF ↓
TMADP-1103-TWP Installation Instructions
Timer adaptor — parallel wiring
PDF ↓
TRADP-1102-TPX Installation Instructions
Timer/remote adaptor combination
PDF ↓

Section 2

Colour Wiring Diagrams — HVAC Damper & Relay Adaptor Configurations

Over 80 full-colour wiring diagrams covering every Hoyme damper and relay adaptor configuration. Each diagram is CSA-certified and inspector-ready. Covers HOM combustion air damper installations, HAC fresh air damper installations, ADP relay adaptor wiring, TMADP timer adaptor sequences, and multi-furnace configurations. Click any diagram number to download the PDF.

How to find your wiring diagram: Diagrams 1–3 cover combustion air (HOM) installations. Diagrams 4–12 cover fresh air and replacement air (HAC/MAC) installations with various ADP adaptor and ventilation fan combinations. If you are unsure which diagram applies to your installation, call 1-800-661-7382.

Diagrams 6–6C3 — 120Vac Ventilation Fan Switch Configurations

#6120Vac ventilation fan switch, adaptor (ADP-1101-05A) and power close replacement air damper c/w relay (-PC) opens during furnace firing.PDF ↓ #6A120Vac ventilation fan switch, adaptor (ADP-1101-05A) and power open replacement air damper (-PO) stays closed during furnace firing.PDF ↓ #6A1Two 120Vac double pole ventilation fan switches and two exhaust fans, adaptor (ADP-1101-05A) and power open replacement air damper (-PO).PDF ↓ #6A2Three 120Vac double pole ventilation fan switches and exhaust fans, adaptor (ADP-1101-05A) and power close replacement air damper c/w relay (-PC), opens during furnace firing.PDF ↓ #6A3Combustion air damper, two separate ventilation and exhaust fans, two adaptors (ADP-1101-05A) and power close replacement air damper (-PC).PDF ↓ #6A4Two 120Vac separate ventilation fans, two adaptors (ADP-1101-05A) and (ADP-1102-TWP), one power close replacement air damper (-PC) opens during furnace firing.PDF ↓ #6A5Two 120Vac ventilation fans, two adaptors (ADP-1101-05A) and (ADP-1102-TWP), one power open replacement air damper (-PO) opens during furnace firing.PDF ↓ #6A6Ventilation switch and fan, two adaptors (ADP-1101-05A) and (ADP-0241-05A), one power open fresh air damper (-PO) opens during venting and furnace firing.PDF ↓ #6A7Two separate 120Vac ventilation fans (primary and secondary), two adaptors (ADP-1102-TWP) and (ADP-1102-10AS), one power open replacement air damper (-PO), opens during furnace firing.PDF ↓ #6A8Two 120Vac ventilation fan switches (primary and secondary), two adaptors (ADP-1102-TWP) and (ADP-1102-10AS), one power close replacement air damper (-PC), opens during furnace firing.PDF ↓ #6A9Heating and cooling system equipped with a steam humidifier using adaptor (ADP-0242-05A).PDF ↓ #6BEconomizer circuit system to ventilate a computer server room with 120Vac vent switch and fan, adaptor (ADP-1101-05A), and one power close air damper (-PC).PDF ↓ #6B1Ventilation switch and large exhaust fan, two replacement fresh air supply ducts with two power open air dampers (-PO), two adaptors (ADP-1101-05A) and (ADP-0241-05A).PDF ↓ #6B2Ventilation switch and fan, two adaptors (ADP-1101-05A) and (ADP-0241-05A), one power close fresh air damper (-PC) opens during venting and furnace firing.PDF ↓ #6B3Forced air furnace having replacement air supply damper (power close - PC).PDF ↓ #6B4Forced air furnace having replacement air supply damper (power close - PC) with relay. Opens during a call for heat and A/C.PDF ↓ #6B5Forced air furnace having replacement air damper (power close - PC) with relay. Opens during a call for heat and with designated ventilation fan. Most common configuration for ADP-1101-05A with power close damper.PDF ↓ #6CVentilation switch, one adaptor (ADP-1102-TWP), one power close replacement air damper (-PC) interconnected with exhaust fan, also opens during furnace firing.PDF ↓ #6C1Ventilation switch, one adaptor (ADP-1102-TWP), one power open replacement air damper (-PO) interconnected with exhaust fan, also opens during furnace firing.PDF ↓ #6C2Ventilation switch, two adaptors (ADP-1102-TWP) and (ADP-0241-05A), one power open replacement air damper (-PO) interconnected with exhaust fan, heating and/or cooling.PDF ↓ #6C3Ventilation switch, two adaptors (ADP-1102-TWP) and (ADP-0241-05A), one power open replacement air damper (-PO) interconnected with exhaust fan, heating and/or cooling, interconnected with A/C.PDF ↓

Diagrams 8–8A9 — Single Furnace, 24Vac Ventilation and ADP-0241 Wiring

#8One 24Vac ventilation switch, one adaptor (ADP-0241-05A), one power close replacement air damper (HAC-0x11-OPC) c/w relay, also opens during furnace firing.PDF ↓ #8AOne 24Vac ventilation switch, one adaptor (ADP-0241-05A), one power open replacement air damper (HAC-0x10-OPO). Does not open during furnace firing.PDF ↓ #8A1One 24Vac ventilation switch, one adaptor (ADP-0241-05A), one power open replacement air damper (-PO). Does not open during furnace firing and turns on 120Vac fan.PDF ↓ #8A2One power open replacement air damper (-PO), one adaptor (RADP-0241-10A) c/w 120Vac controlled receptacle, two 24Vac transformers, two power open air dampers (HAC-0x10-SPO) c/w end switches to control adaptor.PDF ↓ #8A3Forced air furnace with combustion air damper (HOM-0x12-SF2) which also supplies replacement air for 120Vac gas dryer using adaptor (RADP-0241-S10A).PDF ↓ #8A4Forced air furnace with combustion air damper (HOM-0x12-SF2) and power close replacement air damper (HAC-0x10-OPC) which supplies replacement air for 120Vac gas dryer using adaptor (RADP-0241-S10A).PDF ↓ #8A5Forced air furnace with combustion air damper (HOM-0x12-SF2) and power open replacement air damper (HAC-0x10-OPO) which supplies replacement air for 120Vac gas dryer using adaptor (RADP-0241-S10A).PDF ↓ #8A6Forced air furnace with MAC power close air supply damper (MAC-0x11-SPC) which supplies replacement air for 120Vac gas dryer using adaptor (RADP-0241-S10A).PDF ↓ #8A7Forced air furnace with replacement air damper (HAC-0x10-OPC) and MAC power close air supply damper (MAC-0x11-SPC) which supplies replacement air for 120Vac gas dryer using adaptor (RADP-0241-S10A).PDF ↓ #8A8Forced air furnace with power open replacement air damper (HAC-0x10-OPO) and MAC power close air supply damper (MAC-0x11-SPC) which supplies replacement air for 120Vac gas dryer using adaptor (RADP-0241-S10A).PDF ↓ #8A9Forced air furnace with power open replacement air damper (HAC-0x10-OPO) and a ventilation switch/timer that uses adaptor (ADP-0242-05A) to open replacement air damper with ventilation fan and also opens during furnace firing.PDF ↓

Diagrams 8B–8D2 — Two Furnaces, Gas Dryer, and Multi-Fan Configurations

#8BForced air furnace with power close replacement air damper (HAC-0x11-OPC) c/w relay and a ventilation switch/timer that uses adaptor (ADP-0241-05A) to ventilate and also open during furnace firing.PDF ↓ #8B1Forced air furnace with power close replacement air damper (HAC-0x11-OPC) c/w relay and a ventilation switch that uses adaptor (ADP-0241-10A) to ventilate and also open during furnace firing.PDF ↓ #8B4Forced air furnace with combustion air damper (HOM-0x12-SF2) and a power open replacement air damper (HAC-0x10-OPO) that uses adaptor (RADP-1102-S10A) to supply replacement air for 120Vac gas dryer.PDF ↓ #8B5Forced air furnace with power close replacement air damper (MAC-0x11-SPC) and a power close replacement air damper (HAC-0x10-OPC) that uses adaptor (RADP-0242-S10A) to supply replacement air for 120Vac gas dryer.PDF ↓ #8B6Forced air furnace with power close replacement air damper (MAC-0x11-SPC) and a power open replacement air damper (HAC-0x10-OPO) that uses adaptor (RADP-0242-S10A) to supply replacement air for 120Vac gas dryer.PDF ↓ #8B7Forced air furnace with power close replacement air damper (HAC-0x10-OPC) and a ventilation switch/timer that uses adaptor (ADP-0242-05A) to open replacement air damper with ventilation fan and also opens during furnace firing.PDF ↓ #8B8Forced air furnace with power close replacement air damper (HAC-0x10-OPC) and two exhaust/ventilation fans that use two adaptors (ADP-1101-05A) and (ADP-0242-05A) to open damper with fans and also opens during furnace firing.PDF ↓ #8B9Forced air furnace with power close replacement air damper (HAC-0x10-OPC) and two exhaust/ventilation fans that use one adaptor (ADP-1103-TW5) to open replacement air damper with fans and also opens during furnace firing.PDF ↓ #8CTwo forced air furnaces sharing a replacement air duct with a power close fresh air damper (HAC-0x11-OPC) c/w relay controlled by adaptor (ADP-0241-05A).PDF ↓ #8C5Two forced air furnaces sharing a replacement air duct with a power open fresh air damper (HAC-0x10-OPO) with one adaptor (ADP-1102-TWP) for one furnace and a second adaptor (ADP-0241-05A) for the second furnace.PDF ↓ #8C6Two forced air furnaces sharing a replacement air duct with a power close fresh air damper (HAC-0x10-OPC) with one adaptor (ADP-1102-TWP) for one furnace and a second adaptor (ADP-0241-05A) for the second furnace.PDF ↓ #8C7Forced air furnace having a replacement air supply duct together with an exhaust fan venting three bathrooms equipped with 24Vac power open control dampers.PDF ↓ #8DTwo forced air furnaces sharing a replacement air duct with a power close fresh air damper (HAC-0x11-OPC) c/w relay with two adaptors (ADP-0241-05A) controlling the replacement air damper for either furnace.PDF ↓ #8D2Forced air furnace with combustion air damper (HOM-0x11-SF1) and a power close replacement air damper (HAC-0x10-OPC) that uses adaptor (ADP-0241-05A) to open both dampers during heating and cooling cycles.PDF ↓

Diagrams 9–9C1 — TMADP Timer Adaptor Ventilation Configurations

#9Forced air furnace with combustion air damper (HOM-0x11-SF1) and a power close replacement air damper (HAC-0x10-OPC) controlled by adaptor (TMADP-1102-TPX). Damper also opens during furnace firing.PDF ↓ #9AForced air furnace having a power close replacement air damper (HAC-0x10-OPC) and timer adaptor (TMADP-1102-TPX). Damper does not open during furnace firing.PDF ↓ #9A1Forced air furnace having a power open replacement air damper (HAC-0x10-OPO) and timer adaptor (TMADP-1102-TPX). Damper does not open during furnace firing.PDF ↓ #9A2Furnace circulation fan and replacement air damper (HAC-0x10-OPO) controlled by timer adaptor (TMADP-1102-TPX). Includes ADP-1101-05A for additional ventilation fans.PDF ↓ #9A3Forced air furnace with power open replacement air damper (HAC-0x10-OPO). Separate ventilation switch controls exhaust fan plugged into adaptor (TRADP-1102-TPX). Damper does not open during furnace firing.PDF ↓ #9A4Forced air furnace with power open replacement air damper (HAC-0x10-OPO) and two or more exhaust fans controlled by adaptors (TMADP-1102-TPX) and (ADP-1102-TWP). Also opens during furnace firing.PDF ↓ #9A5Same as #9A4 but uses a power close fresh air damper (HAC-0x10-OPC).PDF ↓ #9A6Same as #9A3 but uses a power close fresh air damper (HAC-0x10-OPC).PDF ↓ #9BForced air furnace having a power close replacement air damper (HAC-0x10-OPC) controlled by timer adaptor (TMADP-1102-TPX) and a 3-way ventilation switch.PDF ↓ #9B1Forced air furnace having a power open replacement air damper (HAC-0x10-OPO) controlled by timer adaptor (TMADP-1102-TPX) and a 3-way switch.PDF ↓ #9CSame as #9B but has a designated ventilation switch which functions fully and also an additional 3-way switch to control ventilation fan only.PDF ↓ #9C1Same as #9B1 but has a designated ventilation switch which functions fully and also an additional 3-way switch to control ventilation fan only.PDF ↓

Diagrams 10–12D1 — End Switch Proving and High-Volume Exhaust Fan Configurations

#10Forced air furnace with power close replacement air damper (HAC-0x11-OPC) c/w relay and a designated ventilation switch for exhaust fan that uses adaptor (TMADP-1102-TPX). Also opens during furnace firing.PDF ↓ #11Forced air furnace with combustion air damper (HOM-0x11-SF1) and a power close replacement air damper (HAC-0x11-SPC) c/w end switch that uses adaptor (ADP-1102-TPX). Both dampers open during furnace firing.PDF ↓ #11BDomestic hot water tank with combustion air damper (HOM-0x11-SF1) c/w end switch that uses adaptor (ADP-1102-S5A) to prove combustion air damper is open before power vent runs.PDF ↓ #12Forced air furnace with power close replacement air damper (HAC-0x11-SPC) c/w relay and end switch connected to adaptor (ADP-1102-TPX) to prove damper opens before ventilation fan and furnace fan are allowed to run.PDF ↓ #12ASimilar to #12 but uses adaptor (RADP-1102-TPX) for a plug-in ventilation fan.PDF ↓ #12BForced air furnace with power open replacement air damper (HAC-0x11-SPO) c/w relay and end switch connected to adaptor (ADP-1102-TPX) to prove damper opens before ventilation fan and furnace fan are allowed to run.PDF ↓ #12B1Forced air furnace with power open replacement air damper (HAC-0x11-SPO) c/w relay and end switch connected to adaptor (ADP-1103-TPX). Damper opens during furnace firing.PDF ↓ #12B2Same as #12B1 but uses a power close replacement air damper (HAC-0x10-SPC) that also opens during furnace firing.PDF ↓ #12B3Two exhaust fans operating separately and each connected to an adaptor (ADP-1102-TPX) interlocked to a furnace fresh air damper (HAC-0x11-SPO) that proves to be open before exhaust fans are allowed to run.PDF ↓ #12B4Two exhaust fans operating separately — one connected to adaptor (ADP-1102-TPX) and the other to adaptor (ADP-1103-TPX) — both interlocked to a furnace fresh air damper (HAC-0x10-SPO).PDF ↓ #12CHigh volume kitchen exhaust fan and inlet supply fan interconnected to a forced air heating system with an interlocking inlet power open replacement air damper (HAC-0x10-SPO) c/w end switch and adaptor (ADP-1102-TPX).PDF ↓ #12DFurnace circulation fan and replacement air damper (HAC-0x10-OPO) controlled by exhaust fan switch and adaptor (ADP-1101-05A). Additional power open damper with end switch (HAC-0x10-SPO) and HIGH VOLUME kitchen exhaust fan controlled by adaptor (ADP-1102-TPX).PDF ↓ #12D1Same as #12D but by replacing adaptor (ADP-1101-05A) with adaptor (ADP-1102-TWP), the furnace replacement air damper will now open during furnace firing.PDF ↓

Section 4

Testing & Certification Documentation

Independent test reports and CSA certification documentation for Hoyme Manufacturing products. Includes NRC Canada energy performance testing for the HAE furnace fan air exchanger.