HAC-43
Belimo TFB24-SR-T
Inline Damper
Proportional Blade Positioning · 24 Vac/dc · Spring Return Fail-Safe · 6"–20"
3-wire open/stop/close → HAC-34 (CMB24-3-T)
Modulating, hold last position → HAC-60 (LMB24-SR-T)
Line voltage only → HAC-44 (TFB120) for on/off
What It Does
Proportional blade positioning via 2–10 VDC. Spring return fail-safe. For BAS and DDC analog output control.
The HAC-43 pairs Hoyme's inline damper body with the Belimo TFB24-SR-T spring return modulating actuator. The blade tracks the 2–10 VDC analog signal continuously — 2 VDC holds the blade at minimum position, 10 VDC drives it fully open, and every point between corresponds to a proportional blade position. On power loss, the spring return moves the blade to the fail-safe position set by the action code, regardless of where it was in the modulating range.
Do I Actually Need Modulating Control?
On/off works for most fresh air applications. Modulating is only required when the control strategy demands proportional positioning.
An on/off damper has two states — fully open or fully closed. That is sufficient for most fresh air intake, make-up air, and zone control applications. Modulating control is required when the strategy demands proportional blade positioning:
| Application Strategy | Why Modulating Is Required | Product |
|---|---|---|
| Demand-controlled ventilation (DCV) | CO₂ sensor drives damper proportionally to measured occupancy | HAC-43 |
| Mixed air temperature control | Damper modulates to maintain supply air temperature setpoint | HAC-43 |
| Building pressure management | Damper modulates to maintain pressure differential | HAC-43 |
| VAV fresh air tracking | Fresh air damper tracks variable flow setpoint | HAC-43 |
| Fixed-cycle open/close ventilation | 2-position is sufficient — on/off is simpler and less expensive | HAC-40 (on/off) |
Belimo Series — Control Type Selector
All Belimo-actuated HAC variants. Select by control type and voltage.
| Model | Actuator | Control Type | Voltage | Spring Return | Link |
|---|---|---|---|---|---|
| HAC-40 | TFB24 | On/Off | 24 Vac/dc | Yes | View |
| HAC-44 | TFB120 | On/Off | 100–240 Vac | Yes | View |
| HAC-43 ← You are here | TFB24-SR-T | Modulating 2–10 VDC | 24 Vac/dc | Yes | — |
| HAC-60 | LMB24-SR-T | Modulating 2–10 VDC | 24 Vac/dc | No — holds last | View |
| HAC-34 | CMB24-3-T | Floating point 3-wire | 24 Vac/dc | No — holds last | View |
| HAC-30 | LMB24-3-T | Floating point 3-wire | 24 Vac/dc | No — holds last | View |
| HAC-35 | CMB120-3 | Floating point 3-wire | 100–230 Vac | No — holds last | View |
| HAC-70 | LMX120-3 | Floating point 3-wire | 100–230 Vac | No — holds last | View |
| HAC-90 | FSLF24 US | Fire & Smoke (UL 555S) | 24 Vac | Yes | View |
| HAC-80 | FSLF120 US | Fire & Smoke (UL 555S) | 120 Vac | Yes | View |
Configuration Guide
Select size, action, and end switch. Confirm action code with the mechanical engineer or DDC controls designer before ordering.
| Variant Code | Fail-Safe Action | Signal Direction | End Switch | Part Number Example (10") |
|---|---|---|---|---|
| OPO | Spring-open on power loss | Increasing signal opens blade | No | HAC-1043-OPO |
| SPO | Spring-open on power loss | Increasing signal opens blade | Yes | HAC-1043-SPO |
| OPC | Spring-close on power loss | Increasing signal opens blade | No | HAC-1043-OPC |
| SPC | Spring-close on power loss | Increasing signal opens blade | Yes | HAC-1043-SPC |
Key Specs
Common Questions from the Counter
Answers to what comes up most when specifying the HAC-43.