HAC-F Motorized Flue Damper, CSA Certified, Power Close / Spring Open, 4"–9", Relay and End Switch Included

Hoyme ManufacturingSKU: HAC-0411-SPC-F

Duct Diameter: 4"
Price:
Sale price$318.00 CAD

Contractor? Order through your HVAC wholesaler for your account pricing. Find a wholesaler

No wholesaler account? Buy direct here at list price. Ships across Canada and the US. How to buy

Not sure it's the right part? Call 1-800-661-7382 for free technical support.

Questions before you order? Free technical support at 1-800-661-7382, or see wiring diagrams and install guides.

Contractor? Buy through a Hoyme wholesaler. Custom size or volume order? Request a quote.

Description

CSA-certified motorized round flue control damper for fuel-burning appliance vent and flue runs, 4"–9". Power Close / Spring Open on every unit: closes when powered, springs open on any power loss, keeping the flue clear when the electrical system fails. Relay and end switch included on every unit. Select size only.

Do not substitute a standard HAC on a flue application. A standard HAC with Power Open / Spring Close action fails closed on power loss, sealing the flue while the appliance is firing. On a gas or oil appliance, a closed flue during operation creates carbon monoxide accumulation and back-draft risk. The HAC-F SPC-F actuator is selected specifically because it fails open. The flue is always clear on any power interruption.
✓ Spring Open fail-safe, always. If power is lost while the appliance is firing, the spring opens the damper and the flue is clear; no control system, no signal, no electricity required
✓ Relay and end switch included on every unit: a flue damper without interlock capability is an incomplete safety installation; relay and end switch are not optional on the HAC-F
✓ Canada/USA CSA certified up to 12": the HAC-FS is not an acceptable substitute on code-required applications; AHJ will verify certification
✓ Select size only: 4" through 9"; action, relay, and end switch are pre-configured on every unit; no configuration errors possible
✓ Stall-protected Hoyme spring motor drive: nylon bearings; engineered for the mechanical stresses of a flue run application
Why Power Close / Spring Open, not Power Open / Spring Close
The HAC-F is at rest in the spring-open position (flue clear) when there is no power. Between firing cycles, 24 Vac holds the damper closed to reduce standby heat loss. When the appliance calls to fire, power to the damper is cut and the spring opens it. If power is interrupted at any point, the spring immediately opens the damper. The fail-safe is always in the direction of a clear flue. A Power Open / Spring Close damper is the opposite. It fails closed, sealing the flue during a power interruption while the appliance may still be firing.
1
Appliance calls to fire: the thermostat calls for heat and the HAC-F relay cuts power to the damper motor
2
HAC-F de-energizes: spring opens the damper; flue path is clear
3
End switch confirms open position: the end switch, in series with the thermostat wire to W, closes
4
Appliance fires: if the end switch does not close, the appliance stays off
5
Appliance call ends: 24 Vac powers the HAC-F closed to reduce standby heat loss through the flue
Fail-Safe Direction
Spring Open: flue always clear on power loss
Sizes
4"–9"
Voltage
24 Vac
Action
Power Close / Spring Open (SPC-F)
Included
Relay + end switch, every unit
Certification
CSA certified
Relay adaptor: only if the safety circuit is not 24 Vac
Gas furnace: millivolt / standing pilot system (250mVdc–100Vdc) ADP-0MV2-S5A
Gas furnace or boiler, 24 Vac system No adaptor, wires direct
Boiler or tankless water heater, 110 Vac system ADP-1102-S5A
Need sizes 10"–30"? See the HAC-F Large Diameter listing: Belimo TFB24 actuator, same SPC-F spring-open fail-safe, for commercial flue applications. For non-permitted applications where CSA certification is genuinely not required by the AHJ, see the HAC-FS. Never substitute HAC-FS on a code-required installation.
2-year electrical · 10-year mechanical warranty
CSA certified · Made in Canada · Interlock required, always

Product image is representative only. Actual product may differ in appearance depending on size, configuration, and options selected at order.

Secure checkout

American Express Apple Pay Diners Club Discover Google Pay JCB Maestro Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Contractor? Order through your HVAC wholesaler for your account pricing. Find a wholesaler

No wholesaler account? Buy direct online at list price. Ships across Canada and the US. Order above · How to buy

Not sure it's the right part? Call 1-800-661-7382 for free technical support.

THE CRITICAL DISTINCTION

Why a Flue Damper Must Fail Open, Not Closed

A flue damper has one safety-critical requirement that overrides all other specifications: if power is lost while the appliance is firing, the flue path must stay open. This is why the HAC-F exists as a separate product from the standard HAC.

What happens when a flue damper fails closed

A standard HAC uses Power Open / Spring Close action. It opens when powered and springs closed on power loss. On a fresh air or zone control application that is the correct fail-safe: seal the duct when the system is off. On a flue application, that same behaviour is a safety hazard.

If a standard HAC is installed on a flue run and power is interrupted while the appliance is firing, the spring closes the damper and seals the flue. Combustion gases (including carbon monoxide on gas appliances) have nowhere to go. On a gas furnace or boiler the result is CO accumulation in the appliance casing and back-draft risk into the building.

Standard HAC: Power Open / Spring Close

Springs closed on power loss
Flue seals if power fails during appliance operation
Combustion gases trapped: CO accumulation and back-draft risk
Do not install on a flue application: regardless of size or voltage match

HAC-F: Power Close / Spring Open (SPC-F)

Spring-open on power loss: flue path stays clear if electrical system fails
Powers closed in standby: seals flue between heating cycles, reducing standby heat loss
Spring operates without electricity, without control signal, without BMS
CSA certified, 4"–9" confirmed

If you are uncertain about the fail-safe direction required on a flue application, confirm with the appliance manufacturer's installation instructions before proceeding. Do not substitute a standard HAC or any Power Open / Spring Close damper on a flue run.

HAC-F Motorized Flue Damper, Spring Open fail-safe, SPC-F actuator

HOW THE HAC-F INTERLOCK SEQUENCE WORKS

The HAC-F is powered closed in standby: sealing the flue between heating cycles. When the appliance calls to fire, the wiring cuts power to the damper, the spring opens the flue, and the end switch confirms the flue is clear before the firing cycle begins. On power loss at any point, the spring holds the flue open.

1

Appliance at rest

HAC-F is powered closed. Flue is sealed between heating cycles: reducing standby heat loss. Power is continuously applied to hold the damper closed.

2

Appliance calls to fire

Interlock wiring cuts power to the HAC-F closing motor. Spring opens the damper. End switch confirms the damper has reached the open (flue clear) position.

3

Appliance is released

The end switch is wired in series with the thermostat wire to W. It closes only when the damper is open, so the call reaches the appliance. If it never closes, the appliance stays off.

4

Appliance fires: HAC-F spring-open

Appliance fires with the HAC-F spring-open and power cut: combustion gases vent freely. When the heating cycle ends, power is restored to the HAC-F and the damper closes again. If power fails at any point during the firing cycle, the spring holds the flue open.

Always interlock the HAC-F with appliance controls. Operating a motorized flue damper without appliance interlock is a safety risk and a code violation on permitted installations in most Canadian and US jurisdictions.

Why the end switch is included on every unit

The end switch confirms the HAC-F is in the spring-open (flue clear) position: before the firing cycle begins. Wired in series with the thermostat wire, it holds the appliance off until the flue is clear. A flue damper without an end switch cannot be properly interlocked. Rather than create configurations where a contractor could inadvertently order a flue damper without interlock capability, the end switch is included on every HAC-F unit regardless of size.

Why the relay is included on every unit

The relay switches the damper motor off on a call for heat and back on when the call ends. Together with the end switch it is the hardware that makes the interlock work. A motorized flue damper installed without relay and end switch cannot be properly interlocked with the appliance it serves, which is both a safety risk and a code violation. Both are included on every HAC-F so a complete and safe installation is always possible from a single order.

TWO SERIES: ONE PRODUCT FAMILY

4"–9" or 10"–30", Which Series Do You Need?

Same fail-safe direction. Same relay and end switch on every unit. Same SPC-F action. Different actuator, because larger blade areas require more torque than the Hoyme drive is rated for.

HAC-F 4–9 inch motorized flue damper, stall-protected Hoyme SPC-F drive
4" – 9"

Stall-Protected Hoyme SPC-F Drive

The residential and light commercial series. Uses the stall-protected Hoyme spring motor drive with SPC-F actuator: the same integrated drive family as the HAC and HOM lineup, engineered for the 4"–9" size range.

Gas furnace and boiler flue runs: residential and light commercial
Water heater flue control: atmospherically-vented appliances
CSA certified, 4" through 9"
Field-replaceable parts: serviceable in place

AVAILABLE SIZES

4"

5"

6"

7"

8"

9"

Choose your HAC-F size above ↑
HAC-F Large Diameter 10–30 inch flue damper, Belimo TFB24 actuator
10" – 30"

Belimo TFB24 Actuator

CSA certified to 12". For 14"–30": confirm AHJ acceptance before ordering on code-required applications.

The commercial series. Belimo TFB24 actuator for the torque demanded by larger blade areas: the Hoyme drive is not rated above 9". Same SPC-F spring-open fail-safe. Relay and end switch included on every unit. Belimo TFB24 is field-replaceable through Belimo distributors.

Commercial boiler and furnace flue control
Multi-appliance mechanical rooms: single large-diameter flue
Mechanical engineer-specified Belimo TFB24 applications
Even-inch sizes 10"–30": odd sizes contact factory

AVAILABLE SIZES

10"

12"

14"*

16"*

18"*

20"*

22"*

24"*

26"*

28"*

30"*

* Confirm AHJ acceptance before ordering on code-required applications

Shop HAC-F 10"–30" →

WHAT'S THE SAME ACROSS BOTH SERIES

Power Close / Spring Open (SPC-F) fail-safe on every unit
Relay included on every unit
End switch included on every unit
Size is the only selection: everything else pre-configured
2-yr electrical · 10-yr mechanical warranty
Appliance interlock required: wires direct on 24 Vac, ADP for millivolt

HAC-F vs HAC-FS: Certification Is Not Optional on Permitted Jobs

The HAC-FS uses the same hardware without CSA certification. On any permitted residential or commercial installation where the AHJ will verify equipment, only the HAC-F satisfies the requirement. The HAC-FS is for non-permitted applications where certification is genuinely not required. Never substitute the HAC-FS on a code-required flue application: the difference between a certified and non-certified flue damper is a documented product qualification an AHJ can and will verify.

CONFIGURATION GUIDE

Size Is the Only Decision

Every HAC-F ships with relay included, end switch included, and Power Close / Spring Open action pre-configured. Match the damper to the flue pipe diameter. That's the only selection required.

1

Confirm flue or vent pipe diameter

Match the HAC-F to the flue or vent pipe diameter exactly. Do not size to the appliance collar: size to the pipe. Undersizing or oversizing affects the seal and blade travel.

4"–9": Hoyme SPC-F Drive

4"

5"

6"

7"

8"

9"

10"–30": Belimo TFB24

10"

12"

14"*

16"*

18"*

20–30"*

* Confirm AHJ acceptance before ordering on code-required jobs

2

Confirm certification requirement

CSA certification is confirmed across the full 4"–12" range. For 14"–30" on code-required applications, confirm AHJ acceptance before ordering. If the AHJ requires certification documentation for your specific project, contact Hoyme Manufacturing before placing the order.

4"–12": Order directly

CSA certified. Order directly by size.

14"–30": Confirm AHJ first

Confirm AHJ acceptance before ordering on code-required applications. Contact Hoyme if certification documentation is required.

HAC-FS: Non-certified only

Do not substitute on code-required jobs. HAC-FS is for non-permitted applications only where the AHJ genuinely does not require certification.

3

Wire the interlock, and check whether you need an ADP

The HAC-F must be interlocked with the appliance it serves. On a 24 Vac appliance it wires directly into the thermostat circuit (R, C and W, or TH-TR, TR and TH on the gas valve) with no adaptor. For millivolt safety systems use ADP-0MV2-S5A. For 120 Vac safety controls, call technical support to confirm the adaptor.

ADP-0MV2-S5A

Gas furnace: millivolt / standing pilot / thermopile safety system (250mVdc–100Vdc)

No ADP needed

Gas furnace or boiler, 24 Vac: wires direct, no ADP · most common

ADP-1102-S5A

Boiler or tankless water heater, 110 Vac · up to 5A load

ADP-1102-10A

Boiler or tankless water heater, 110 Vac · up to 10A load · confirm appliance spec label

View Full ADP Series →

HOW TO READ YOUR PART NUMBER

4"–9" SERIES: HOYME SPC-F DRIVE

HAC

Product

–
08

Size (8")

11

Relay incl.

–
S

End switch

PC

Power Close

–
F

Flue suffix

10"–30" SERIES: BELIMO TFB24

HAC

Product

–
16

Size (16")

41

TFB24+relay

–
S

End switch

PC

Power Close

–
F

Flue suffix

SIZE CODES (4"–9")

04=4" · 05=5" · 06=6" · 07=7" · 08=8" · 09=9"

SIZE CODES (10"–30")

10=10" · 12=12" · 14=14" · through 30=30"

MOTOR CODE

11=Hoyme drive + relay (4"–9") · 41=Belimo TFB24 + relay (10"+)

ACTION + SUFFIX

SPC-F = end switch · Power Close · Flue (spring opens on power loss)

COMPLETE PART NUMBER REFERENCE

4"–9" HOYME DRIVE

HAC-0411-SPC-F  4"

HAC-0511-SPC-F  5"

HAC-0611-SPC-F  6"

HAC-0711-SPC-F  7"

HAC-0811-SPC-F  8"

HAC-0911-SPC-F  9"

10"–20" BELIMO TFB24

HAC-1041-SPC-F  10"

HAC-1241-SPC-F  12"

HAC-1441-SPC-F  14"*

HAC-1641-SPC-F  16"*

HAC-1841-SPC-F  18"*

HAC-2041-SPC-F  20"*

22"–30" BELIMO TFB24

HAC-2241-SPC-F  22"*

HAC-2441-SPC-F  24"*

HAC-2641-SPC-F  26"*

HAC-2841-SPC-F  28"*

HAC-3041-SPC-F  30"*

* Confirm AHJ acceptance

WHY HOYME

The Right Actuator for the Right Size, Not One Actuator for Everything

The HAC-F uses two different actuators across its size range, not because of cost, but because larger blade areas require more torque than the Hoyme drive is rated for. Each actuator is matched to the torque the application demands.

Hoyme HAC-F 4–9 inch, SPC-F spring motor drive
4"–9"

Stall-Protected Hoyme SPC-F Drive

The same 24 Vac stall-protected Synchron motor and nylon bearing assembly used across the HAC and HOM lineup: proven in residential and light commercial installations across Canada and the northern US. The SPC-F designation confirms the spring-open fail-safe configuration built into the actuator itself.

Stall-protected, not circuit-protected

Holds against ice load or mechanical obstruction without tripping. Clears the obstruction when conditions change: does not leave the blade in an unknown position.

Serviceable in place

Replacement motor kits, microswitch kits, and spring return kits are available through Hoyme wholesalers. A motor failure does not require replacing the full HAC-F assembly.

Same drive family as HAC and HOM

One service part across your entire Hoyme specification. Counter staff and service technicians who know the HAC drive know the HAC-F drive.

Voltage

24 Vac

Type

Stall-protected Synchron

Fail-safe

Spring open (SPC-F)

Service parts

Field-replaceable

HAC-F Large Diameter 10–30 inch, Belimo TFB24 actuator
10"–30"

Belimo TFB24 Actuator

At 10" and above, blade surface area increases to the point where the Hoyme drive is not rated for the torque the application demands. The Belimo TFB24 is specified for this size range because it delivers the torque needed to move larger flue blades reliably under the static pressure and temperature conditions of a commercial flue run.

Matched to the torque requirement

Not an upgrade or a downgrade from the Hoyme drive: the actuator matched to what larger blade areas actually demand. The Hoyme drive is right for 4"–9". The TFB24 is right for 10"–30".

Available through Belimo distributors

On a commercial installation, a failed actuator is not a residential service call. It's a building shutdown. TFB24 availability through Belimo's distribution network is a practical advantage on large commercial jobs.

Field-replaceable without replacing the damper

The TFB24 mounts to the HAC-F damper body and can be replaced in place. A failed actuator does not require replacing the full damper assembly. Confirm replacement actuator model matches installed unit before ordering.

Voltage

24 Vac/dc

Type

On/off spring return

Fail-safe

Spring open (SPC-F)

Service parts

Belimo distributors

WHAT'S THE SAME ACROSS BOTH ACTUATOR FAMILIES

Spring open fail-safe

SPC-F action on every unit regardless of size. The flue path is always clear on any power interruption, 4" or 30".

CSA certified, 4" to 12"

Full 4"–12" range certified. AHJ confirmation required for 14"–30" on code-required applications.

Relay + end switch included

Every unit ships interlock-ready. No configuration required. Select size and order.

2-yr electrical · 10-yr mechanical

Full Hoyme warranty covering the actuator, damper body, relay and end switch.

Why two actuators instead of one?

As flue pipe diameter increases, blade surface area increases and so does the torque required to reliably open and close the blade against duct static pressure. At 10" and above, the Hoyme drive is not rated for the torque the application demands: specifying it there would be engineering the wrong actuator into a safety-critical installation. The Belimo TFB24 is specified from 10" upward because it delivers what those sizes actually need. The two-actuator approach is the technically correct answer to a torque problem, not a product decision.

COMMON QUESTIONS

HAC-F Motorized Flue Damper FAQs

Questions contractors and counter staff ask most often: answered directly from the product.

Can I use a standard HAC instead of the HAC-F on a flue run? +

No: do not substitute a standard HAC on any flue application.

This is a safety issue, not a preference.

A standard HAC uses Power Open / Spring Close action. It springs closed on power loss. On a flue application, if power is interrupted while the appliance is firing, the spring seals the flue. Combustion gases including carbon monoxide have nowhere to go. On a gas or oil appliance that creates CO accumulation in the appliance casing and back-draft risk into the building.

The HAC-F uses Power Close / Spring Open (SPC-F) action specifically because this is the code-correct fail-safe for a flue damper: the flue path is always clear on any power interruption. Do not substitute a standard HAC on a flue application regardless of size or voltage match.

Why does the HAC-F close when powered: isn't Power Close backwards for a flue damper? +

It seems counterintuitive until you understand the fail-safe logic. The HAC-F is spring-open when there is no power: the flue is always clear when the damper is at rest. The end switch confirms this open position before the appliance is allowed to fire.

Once the end switch closes and completes the circuit to W, the appliance fires with the HAC-F spring-open: combustion gases vent freely through the open flue. After the heating cycle ends, power is restored to the HAC-F and the damper closes again, sealing the flue in standby and reducing heat loss between firing cycles.

If power is lost at any point (before, during, or after firing) the spring holds the damper open and the flue stays clear. The fail-safe is always toward an open flue. Power holds the damper closed between calls. The spring is what matters.

Does the HAC-F need to be interlocked with the appliance? +

Yes, always. This is a safety requirement, not a recommendation. The appliance must not fire until the HAC-F end switch confirms the damper is in the spring-open (flue clear) position.

Without interlock, the appliance fires regardless of damper position, which means if the damper fails to open (motor fault, ice load, mechanical obstruction), the appliance fires into a partially or fully obstructed flue. That is the unsafe installation. With the HAC-F wired into the safety circuit as instructed, the appliance cannot fire unless the end switch confirms the flue is clear.

Operating a motorized flue damper without appliance interlock is a safety risk and a code violation on permitted installations in most Canadian and US jurisdictions. On 24 Vac, wire the HAC-F directly into the thermostat circuit as its installation instructions show. For millivolt or 120 Vac safety controls, see the ADP series page for model selection.

What happens if the HAC-F fails to open when the appliance calls to fire? +

With the interlock wired correctly, the appliance cannot fire. The HAC-F end switch is in series with the thermostat wire, so the safety circuit stays open until the damper is in the spring-open (flue clear) position. If the damper fails to reach the open position (motor fault, mechanical obstruction, ice load) the end switch does not close and the appliance does not fire.

This is the correct fail-safe behaviour. The system fails safe: the appliance stays off rather than firing into an obstructed flue. This is why interlock is required on every HAC-F installation and why the end switch and relay are included on every unit.

Do I need an ADP relay adaptor for flue damper interlock? +

Only if the safety circuit is not 24 Vac:

ADP-0MV2-S5A

Gas furnace: millivolt safety system, standing pilot, thermopile or thermocouple (250mVdc–100Vdc). Only model rated for millivolt safety circuits.

No ADP needed

Gas furnace or boiler, 24 Vac: the HAC-F wires directly into the thermostat circuit. No ADP needed. Most common.

ADP-1102-S5A

Boiler or tankless water heater, 110 Vac, up to 5A load.

ADP-1102-10A

Boiler or tankless water heater, 110 Vac, up to 10A load. Confirm appliance nameplate before ordering.

See the ADP series page for full model lineup and wiring diagrams.

What's the difference between the HAC-F and the HAC-FS? +

The HAC-F is CSA certified. The HAC-FS uses the same damper body and actuator without CSA certification. It is for non-permitted applications where the AHJ genuinely does not require certification on the flue damper component.

On any permitted residential or commercial installation in Canada or the US where the AHJ will verify equipment, only the HAC-F satisfies the requirement. The difference between a certified and non-certified flue damper is a documented product qualification: an AHJ can and will verify it.

Never substitute the HAC-FS on a code-required flue application. The HAC-FS is not a cost-saving alternative on permitted jobs. It is a different product for a different application.

My flue is 10" or larger, which HAC-F do I order? +

Order the HAC-F Large Diameter series, Belimo TFB24 actuator, available in even-inch sizes from 10" through 30". Same Power Close / Spring Open fail-safe. Relay and end switch included on every unit.

The standard HAC-F (4"–9") uses the stall-protected Hoyme SPC-F drive: the Hoyme drive is not rated for the torque required at 10" and above. The Belimo TFB24 is specified from 10" upward because it delivers the torque larger blade areas demand.

CSA certification is confirmed to 12". For 14"–30" on code-required applications, confirm AHJ acceptance before ordering. Odd-inch sizes not available in the standard range. Contact Hoyme Manufacturing for non-standard diameters.

Why are the relay and end switch included on every unit: can I order without them? +

No: the relay and end switch are included on every HAC-F because a motorized flue damper installed without appliance interlock capability is an incomplete and unsafe installation. The end switch confirms the flue is clear before firing. The relay switches the damper motor with the call for heat. Both are required for a complete interlock.

Rather than create configurations where a contractor could inadvertently order a flue damper without interlock capability, both components are included on every unit regardless of size. There is no version of the HAC-F without relay and end switch: the complete interlock-ready assembly is the product.

Can the HAC-F be used on a dryer exhaust? +

No. The HAC-F is designed for fuel-burning appliance flue and vent runs, not dryer exhaust. The dryer exhaust environment (elevated temperature, lint, high humidity) is outside the HAC-F's listed application. Lint accumulation in the motor assembly causes premature failure.

For gas dryer exhaust applications requiring back draft protection, use a BDH Back Draft Hood at the wall termination: designed for the dryer exhaust environment. For gas dryer interlock requirements, see the ADP series for the correct relay adaptor for your application.

Can I get a replacement Belimo TFB24 if the actuator fails on the large diameter unit? +

Yes: the Belimo TFB24 is available through Belimo distributors. The actuator mounts to the HAC-F damper body and can be replaced in the field without replacing the full damper assembly. Confirm the replacement actuator model matches the installed unit before ordering.

For the 4"–9" series, replacement Hoyme motor kits, microswitch kits, and spring return kits are available through Hoyme wholesalers, the same service parts as the HAC and HOM lineup.

Who do I call if I'm unsure which product or configuration is right for my job? +

Call Hoyme technical support directly. Have your flue pipe diameter, appliance type, system voltage, and whether the job is permitted ready, and we'll confirm the right HAC-F size and series, and whether you need an ADP, before you order.

READY TO ORDER

The Flue Is Always Clear. Every Time Power Is Lost.

Match the HAC-F to your flue pipe diameter, check whether your appliance needs an ADP, and order. Everything else is pre-configured. Call technical support if you need confirmation before the order goes in.

✓ Spring opens on power loss: flue always clear
✓ Relay + end switch included: interlock-ready out of the box
✓ CSA certified, 4" to 12" confirmed
✓ 4"–30": Hoyme drive or Belimo TFB24 matched to size
✓ 2-yr electrical · 10-yr mechanical warranty
✓ Do not substitute a standard HAC on a flue application