ADP - Interface Relay Adaptors - Complete List with Details
Quick links to Adaptors on this page
...Millivolt Adaptors
| Hoyme Milivolt dc Adaptors | |
|
|
|
| HMI Hoyme ADP- 0MV2 - S5A | |
|
Interlocking Relay Adaptor: for combustion fresh air inlet damper HOM - 24Vac; connects to 250 mVdc to 100 Vdc - 2 wire safety control system. Damper proves to be open before fire starts.comes with 2 relays, printed circuit & Test/Run switch. Also ideal for commercial use. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-0MV2-S5A |
|
|
|
|
| Hoyme 110Vac Coil Adaptors | |
|
|
|
| HMI Hoyme ADP- 1101 - 05A | |
|
Adaptor control centre combines 120Vac with 24Vac circuits. Interconnects the thermostat fan cycle, primary exhaust fan switch and the furnace circulating fan. Fresh air damper, if installed, also opens simultaneously with exhaust fan. Will not interfere with air conditioning controls. Comes with 120Vac coil with 24Vac switching for 24Vac dampers and thermostat circuits. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-1101-05A #5. 120Vac vent switch, combustion air, & replacement air #5A. 120Vac vent switch, combustion air & replacement air(2 furnaces) #5B. 120Vac vent switch, combustion air(2 furnaces), replacement air #5B1. 120Vac vent switch, combustion air(2 furnaces), replacement air #5B2. Two 120Vac vent switches, with Primary & Secondary vent fan, replacement air damper Power Open. #5B3. Two 120Vac vent switches, with Primary & Secondary vent fan, replacement air damper Power Close. #5C. 120 Vac two double pole vent switches with two exhaust fans , combustion air & replacement air #6. 120Vac vent switch & replacement air damper opens during firing, Power Close #6A. 120Vac vent switch & replacement air damper, Power Open #6A1. Two 120Vac seperate double-pole vent switchs & fans, and replacement air damper, Power Open #6A2. Two 120Vac seperate double-pole vent switchs & fans, and replacement air damper, Power Close #6A3. Combustion Air, Two 120Vac separate vent switchs and fans, Two Adaptor 1101-05A's & replacement air damper, Power Close #6A4. Two 120Vac separate vent switchs and fans, and an 1102-TWP Adaptor, replacement air damper, Power Close #6A5. Two 120Vac separate vent switchs and fans, and an 1102-TWP Adaptor, replacement air damper, Power Open #6A6. 120Vac vent switch, Adaptor 1101-05A and replacement air damper, Power Open with ADP-0241-05A #6B. Economizer Circuit System to Ventilate a Computer Server Room #6B1. Two Replacement fresh air supply ducts with dampers, exhaust fan and Vent Switch #9A2. TMADP-1102-TPX combined with this ADP-1101-05A Adaptor #12D. ADP-1102-TPX combined with this ADP-1101-05A Adaptor |
|
|
|
|
| HMI Hoyme ADP- 1101 - 10AS | |
This Adaptor ADP-1101-10AS is an automatic control switch designed to operate with ADP-1101-05A or with ADP-1102-TWP to: 1. Be connected to two exhaust fans, either one to operate from its own exhaust fan switch but is interlocked to prevent the two exhaust fans from operating at the same time; 2. To simultaneously turn on the furnace circulation fan for either exhaust fan; 3. To simultaneously open a Replacement/Ventilation damper (if used) for either exhaust fan. Note: If the replacement air damper is to also open during the firing cycle of the furnace, replace ADP-1101-05A with ADP-1102-TWP.
Installation instructions - Printer friendly (pdf) |
|
| Hoyme 24Vac Coil Adaptors | |
|
|
|
| HMI Hoyme ADP- 0241- 05A | |
|
This Relay Adaptor may be used as an automatic switch having a 24Vac coil and 120Vac contact points to control a line voltage circuit for up to a 5 amp draw. i.e. Exhaust Fan. Adaptor can also be used 100% for 24Vac switching (See ADP-1101). Switching 24Vac dampers and thermostat circuits use 5A type only (ADP-0241-05A). For 120Vac fan control, use 10A type only (ADP-0241-10A). Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-0241-05A #6A6. 120 Vac Vent switch and fan, an ADP-1101-05A & an ADP-0241-05A, replacement air damper (Power Open) #6B1. Two Replacement fresh air supply ducts with dampers, exhaust fan and Vent Switch #6C2. Vent switch, replacement air - power open, interconnected with exhaust fan, heating cycle and/or cooling cycle. #6C3. Vent switch, replacement air damper (Power Open), interconnected with exhaust fan heating cycle and/or cooling cycle. #6C4. Vent switch, replacement air damper (Power Open), interconnected with exhaust fan heating cycle and/or cooling cycle. #7. 24VAC vent switch, combustion air, & replacement air #7A. 24Vac vent switch, combustion air, & replacement air with two exhaust fans and two individual timers #8. 24VAC vent switch & replacement air opens during firing #8A. 24Vac vent switch & replacement air damper Power Open #8B. 24Vac vent switch with relay, replacement air damper Power Close #8B2. 24 Vac Vent Switch, Forced air furnace with replacement air damper (Power Open) with exhaust fan #8C. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air Power Closed Damper #8C1. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air Power Open Damper #8C2. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air Power Open Damper #8C3. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air Power Open Damper #8C4. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air Power Open Damper #8C5. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air Damper (Power Open) #8C6. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air Damper (Power Close) |
|
|
|
|
| HMI Hoyme ADP- 0242- 05A | |
|
This Adaptor has two 24Vac Relays. The contact points of one relay can be used to control a 120Vac circuit of up to 5 amp draw such as running a 120Vac exhaust fan. This Adaptor can also be used 100% for 24Vac switching. Installation instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-0242-05A |
![]() |
|
|
|
| HMI Hoyme ADP- 0241- 10A | |
|
This Relay Adaptor may be used as an automatic switch having a 24Vac coil and 120Vac contact points to control a line voltage circuit for up to a 10 amp draw. i.e. Exhaust Fan. Adaptor can also be used 100% for 24Vac switching (See ADP-1101). Switching 24Vac dampers and thermostat circuits use 5A type only (ADP-0241-05A) and for 120Vac fan control, use 10A type only (ADP-0241-10A). Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-0241-10A #7A1. 24Vac vent switch, combustion air, & replacement air with two exhaust fans & two individual timers Power Close #8A1. 24Vac vent controlled by switch & replacement air damper Power Open #8B1. 24Vac vent switch with relay, replacement air damper Power Close with exhaust fan #8B3. 24Vac Vent Switch, Forced air Furnace with replacement air damper (Power Open) with exhaust fan |
|
| HMI Hoyme RADP- 0241- 10A | |
|
This Interface Adaptor comes with one relay having a 24Vac Coil and 120Vac contacts together with a split Duplex Receptacle. This Adaptor with the split Receptacle allows for a 24Vac circuit such as a furnace safety control or a 24Vac damper with end switch to control a PLUG-IN 120Vac fan for ventilation, zone or fresh air. The split Receptacle provides a continuous and a controlled120Vac power supply. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the RADP-0241-10A #8A2. Replacement air damper Power Open with 120Vac plug-in vent fan & dampers controlled by vent switch |
|
|
|
|
| HMI Hoyme RADP- 0241- S10A | |
|
This Interface Adaptor comes with one relay having a 24Vac Coil and 120Vac contacts together with a split Duplex Receptacle. This Adaptor with an on/off switch functions as a control centre to supply 120Vac for a plug-in type gas dryer and is INTERLOCKED with the combustion air damper(HOM-0x12-SF2) proving it to be open before dryer operates. It can also be used to operate a replacement air damper and turn on the furnace fan to assist with air movement during the drying cycle. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the RADP-0241-S10A #8A3. Forced air furnace with Combustion air damper which also supplies replacement air for 120 Vac Gas Dryer #8A4. Forced Air Furnace having a combustion air supply duct and also a replacement air duct(PC) that serves as an air supply for a 120Vac gas dryer. #8A5. Forced Air Furnace having a combustion air supply duct and also a replacement air duct(PO) that serves as an air supply for a 120Vac gas dryer. #8A6. Forced air furnace with MAC air damper which also supplies replacement air for 120 Vac gas dryer. #8A7. Forced Air Furnace having a MAC air supply duct and also a replacement air duct(PC) that serves as an air supply for a 120Vac gas dryer. #8A8. Forced Air Furnace having a MAC air supply duct and also a replacement air duct(PO) that serves as an air supply for a 120Vac gas dryer. |
|
|
|
|
| HMI Hoyme RADP- 0242- S10A | |
|
This Interface Adaptor comes with one relay having a 24Vac Coil and 120Vac contacts together with a split Duplex Receptacle. This Adaptor with an on/off switch functions as a control centre to supply 120Vac for a plug-in type gas dryer and is INTERLOCKED with the combustion air damper(HOM-0x12-SF2) proving it to be open before dryer operates. It can also be used to operate a replacement air damper and turn on the furnace fan to assist with air movement during the drying cycle. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the RADP-0241-S10A #8B4. Forced Air Furnace having a combustion air supply duct that serves the furnace and a 120Vac gas dryer and also a fresh air replacement air duct(Power Open) #8B5. Combustion air supply duct for 120Vac Gas Dryer with a fresh air Power Close Damper #8B6. Combustion air supply duct for 120Vac Gas Dryer with a fresh air Power Open Damper. |
|
|
|
|
| Hoyme 110 & 24Vac Coil Adaptors | |
| HMI Hoyme ADP- 1102 - TPX | |
|
120Vac / 24Vac Interlocking Relay Adaptor Control Center: to control 24Vac ventilation fresh air inlet damper with end switch connected to 120Vac exhaust fan. Damper proves to be open before exhaust fan runs. Also turns on furnace circulation fan. c/w 2 relays: 120Vac and 24Vac. Contacts 10 Amps. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-1102-TPX #11. Vent switch, combustion air, & interlocking replacement air #12. Vent switch & interlocking replacement air - Power Close Damper #12B. Vent switch & interlocking replacement air - Power Open Damper #12B3. Vent switch & interlocking replacement air - Power Open Damper #12B4. Vent switch & interlocking replacement air - Power Open Damper #12C. High volume Kitchen Exhaust fan interconnected to a Forced Air Heating System, replacement air & inlet fan interlocked with a Power Open Damper #12D. High volume Exhaust fan interconnected to a Forced Air Heating System, replacement air & inlet fan interlocked with a Power Open Damper #12D1. High volume Exhaust fan interconnected to a Forced Air Heating System, replacement air & inlet fan interlocked with a Power Open Damper |
|
|
|
|
| HMI Hoyme ADP- 1102 - TWP | |
|
This Adaptor is an automatic switch to actuate a 24Vac Replacement/Ventilation damper to open during the exhausting of air or during the firing cycle of the furnace. By connecting the Adaptor 120Vac relay coil to the controlled line voltage of an exhaust fan and connecting the 24Vac circuit to the furnace terminals, the exhaust fan, the furnace fan and the inlet damper will all operate simultaneously. The replacement damper will also operate individually during the firing of the furnace. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-1102-TWP #6A7. Two 120Vac vent switches, One Primary and One Secondary Vent Fan replacement air damper, Power Open with ADP-1102-TWP & ADP-1101-10AS #6A8. Two 120Vac vent switches, One Primary & One Secondary Vent Fan, Replacement air damper, Power Close with ADP-1101-10AS & ADP-1102-TWP #6C3. Vent switch, replacement air damper (Power Open), interconnected with exhaust fan heating cycle and/or cooling cycle. #8C5. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air Damper (Power Open) #8C6. Two Forced Air Furnaces sharing a replacement air supply duct controlled by one fresh air Damper (Power Close) #12D1. 120 Vac vent switch, ADP-1102-TWP and replacement air damper, Power Open with High volume Kitchen Exhaust fan interconnected to a Forced Air Heating System, replacement air with inlet fan interlocked with a separate damper (Power Open) |
|
| HMI Hoyme ADP- 1102 - TW5 | |
|
This Adaptor ADP-1102-TW5 is an automatic relay control switch specifically designed, but not limited, to accommodate two separate exhaust fans in a dwelling interconnected to one furnace having a replacement air duct and (if used) a replacement air damper. A controlled 120Vac signal from one exhaust fan and/or a controlled 24Vac signal (or dry contacts) from a second exhaust fan will simultaneously turn on the furnace circulation fan and open the replacement air damper. Installation instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-1102-TW5 |
|
|
|
|
| HMI Hoyme ADP- 1102 - 10A | |
|
120Vac Interlocking Relay Adaptor: for combustion fresh air inlet dampers and Flue Dampers interlocking with TANKLESS WATER HEATERS. This adaptor accomodates a safety control system that might differ from the load capacity (i.e circulating pump). Dampers prove to be open before fire starts. Ideal for residential and commercial use. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-1102-10A |
|
|
|
|
| HMI Hoyme ADP- 1102 - S5A | |
|
120Vac Interlocking Relay Adaptor: for combustion fresh air inlet dampers and Flue Dampers using 120Vac safety control systems. Dampers prove to be open before fire starts. c/w 120Vac relay, 24Vac relay & Test/Run switch. Also ideal for commercial use. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-1102-S5A |
|
|
|
|
| HMI Hoyme RADP- 1102- TPX | |
|
This Adaptor acts as an automatic control centre to:
1) open a 24Vac motorized air Inlet Damper with an End Switch that proves to be open (interlocked) before 2)starting a plug-in type Exhaust Fan and 3) simultaneously turning on a furnace circulation fan. It has two Relays and a split Duplex Receptacle, one side live and the other side controlled. If using a Damper without an End Switch, a jumper wire is required between Adaptor terminals #1 and #4. All items will then turn on simultaneously. The Adaptor is controlled with a Ventilation Switch and/or a Timer. Installation Instructions - Printer friendly (pdf)
Colored Wiring Diagrams used with the RADP-1102-TPX |
![]() |
|
|
|
| HMI Hoyme TMADP- 1102 - TPX | |
|
Automatic Relay Adaptor Control Center: for ventilation fresh air, comes with 24Vac Interval Timer. Interconnects and turns on a 120Vac exhaust fan, furnace circulation fan and opens a 24Vac fresh air inlet damper simultaneously as per times designated. Responds also to the regular 120Vac manual ventilation switch.comes with 2 relays: 120Vac and 24Vac. Contacts 10 Amps. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the TMADP-1102-TPX #9. Timer, vent switch, combustion air, and replacement air #9A. Timer, vent switch and replacement air, Power Close #9A1. Timer, vent switch and replacement air, Power Open #9A2. Timer Adaptor combined with ADP-1101-05A Adaptor #9A4. 120Vac Vent Fans, Vent Switch, Timer Adaptor with 1102-TWP Adaptor, Replacement air damper (Power Open) #9A5. 120Vac Vent Fans, Vent Switch, Timer Adaptor with 1102-TWP Adaptor, Replacement air damper (Power Close) #9B. Timer, 3-way vent switch and replacement air #9B1. Timer, vent switch, replacement air damper, Power Open and a 3-way ventilation switch #9C. Timer, vent switch, replacement air, Power Close, and an exhaust fan with 3-way ventilation switch #9C1. Timer, vent switch, replacement air, Power Open, and an exhaust fan with 3-way ventilation switch #10. Timer, vent switch and replacement air opens during firing |
|
|
|
|
| HMI Hoyme TRADP- 1102- TPX | |
|
This TRADP-1102-TPX adaptor c/w two relays, a 24Vac interval timer and a split duplex receptacle. This adaptor acts as an automatic control centre to simultaneously turn on a furnace fan, start a plug-in type exhaust fan and open a 24Vac motorized air inlet damper. The duplex receptacle is split to accommodate a live outlet and a controlled 120Vac outlet for the fan. A designated ventilation switch (manual override switch) may be added for direct control to override the timer. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the TRADP-1102-TPX #9A3. Plug-in exhaust fan controlled by a designated ventilation switch and automatic interval timer Power Open Damper #9A6. Plug-in exhaust fan controlled by a designated ventilation switch and automatic interval timer Power Close Damper |
|
|
|
|
| HMI Hoyme ADP- 1103 - TPX | |
|
This ADP-1103-TPX adaptor with 3 relays acts as a control centre activated by a manual 120Vac ventilation switch to: (1) Open a 24Vac fresh air inlet damper equipped with an end switch; (2) Simultaneously turn on the furnace fan; (3) Turn on a 120Vac exhaust fan after damper proves to be open (interlocked); and (4) In addition, the inlet damper will also open during furnace firing. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-1103-TPX #12B1. Vent switch and interlocking replacement air damper - Power Open #12B2. Vent switch and interlocking replacement air - Power Close #12B4. Vent switches and interlocking replacement air damper - Power Open |
![]() |
|
|
|
| HMI Hoyme ADP- 1103 - TWP | |
|
This Adaptor is an automatic switch to actuate a 24Vac Replacement/Ventilation damper to open during the exhausting of air or during the firing cycle of the furnace. By connecting the Adaptor 120Vac relay coil to the controlled line voltage of an exhaust fan and connecting the 24Vac circuit to the furnace terminals, the exhaust fan, the furnace fan and the inlet damper will all operate simultaneously. The replacement damper will also operate individually during the firing of the furnace.
Installation Instructions - Printer friendly (pdf) |
|
|
|
|
| HMI Hoyme ADP- 1103 - TW5 | |
This Adaptor ADP-1103-TW5 is an automatic control switch which is designed but not limited to accommodate two separate exhaust fans in a dwelling having one furnace and (if used) a replacement air damper. A controlled 120Vac signal from one exhaust fan and/or a 24Vac signal (or dry contacts) from a second exhaust fan will simultaneously turn on the furnace circulation fan and open the replacement air damper. Added is a relay to also open the damper during furnace firing. Installation instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-1103-TW5 |
|
| HMI Hoyme TMADP- 1103 - TPX | |
|
This TMADP-1103-TPX adaptor with three relays and a 24Vac interval timer, together with a central ventilation switch, acts as an automatic/manual control centre to simultaneously turn on a principal exhaust fan, turn on a furnace fan, and open a fresh air inlet damper (If used). In addition, this adaptor also opens the inlet damper during furnace firing. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the TMADP-1103-TPX |
![]() |
|
|
|
| Hoyme Adaptors Switches No Relays | |
| HMI Hoyme ADP- 0240- 3WS | |
|
This ADP-0240-3WS Adaptor acts as a ready-built manual override 3-Way Switch for Power Open Dampers. This provides direct control of the opening of the damper when desired. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-0240-3WS |
|
|
|
|
| HMI Hoyme ADP- 0240- 1WS | |
|
This ADP-0240-1WS Adaptor acts as a ready-built On/Off Switch for a variety of uses. This provides direct control to manually open Power Closed dampers as needed. As well as any number of situations requiring a ready-made 24Vac On/Off switch box with terminal strips for ease of installation. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the ADP-0240-1WS |
|
|
|
|
| HMI Hoyme TMADP- 0240- 3WS | |
|
This TMADP-0240-3WS Adaptor acts as a ready-built manual override 3-Way Switch for Power Open Dampers. This also has a timer to prevent the damper from opening during specified times over a 24 period, This provides direct control of the opening of the damper when desired. Installation Instructions - Printer friendly (pdf) Colored Wiring Diagrams used with the TMADP-0240-3WS
#3A3. Combustion air damper and replacement air damper-power open with TMADP-0240-3WS |
|
Last Updated (Friday, 28 December 2012 16:34)