Colored Wiring Diagram #8B2
Forced Air Furnace with a replacement air supply duct controlled by a fresh air Power Open Damper
HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations.
Diagram #8B2: Forced Air Furnace having a replacement air supply duct together with an exhaust fan controlled by a designated ventilation switch and/or bathroom timer.
1. Replacement Air Control Damper, Power Open (HAC-0x10- OPO)
2. Ventilation Switch and/or bathroom timer.
3. 2ea - 24Vac Relay Adaptors (ADP-0241-05A) to function together as a control centre.
OPERATION:
1. Replacement Air Damper opens during Furnace firing.
2. Ventilation Switch and/or bathroom timer turns on Ventilation Fan, opens Replacement Air Damper and turns on Furnace Fan simultaneously.
3. Optional Switch (i.e. toggle switch, timer, de-humidistat) allows full control of Replacement Air damper to open as required.
Printer friendly (pdf) - (Opens in a new window)