Home Support Colored Wiring Diagrams #5 - #6B2 #6A

Colored Wiring Diagram #6A

120Vac vent switch, Adaptor 1101 and replacement air damper, Power Open
 
HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations.

Color Wiring Diagram #6A

Diagram #6A: Forced Air Furnace having a replacement air supply duct together with an exhaust fan controlled by a designated ventilation switch and/or bathroom timer .
 
1. Replacement Air Control Damper (PO) (HAC-0x10-OPO)  
2. Ventilation Switch and/or bathroom timer to supply Controlled 120Vac to furnace area 
3. An optional ON/OFF Switch. 
4. Relay Adaptor (ADP-1101-05A) to function as a control centre.
 
OPERATION:  
1. Furnace fires with thermostat signal. 
2. Ventilation Switch and/or bathroom timer turns on the Ventilation Fan, the Furnace Fan and opens the Ventilation Damper simultaneously with the damper connected to Adaptor Terminal #1. 
3. Optional Switch (i.e. toggle switch, timer, de-humidistat) connected between #1 and #2 of the Adaptor allows full control of the Replacement Air Damper to open as required.
 
N.B. Replacement Air Damper is not affected by the ‘Manual’ setting of the furnace fan.