ADP - 1101 - 10AS - (120Vac controlled line voltage to Switch 24Vac)

HMI Interface Relay Adaptors


HMI   Hoyme ADP- 1101 - 10AS
This Adaptor ADP-1101-10AS is an automatic control switch designed to operate with ADP-1101-05A or with ADP-1102-TWP to:
1. Be connected to two exhaust fans, either one to operate from its own exhaust fan switch but is interlocked to prevent the two exhaust fans from operating at the same time;
2. To simultaneously turn on the furnace circulation fan for either exhaust fan;
3. To simultaneously open a Replacement/Ventilation damper (if used) for either exhaust fan.

Note: If the replacement air damper is to also open during the firing cycle of the furnace, replace
ADP-1101-05A with ADP-1102-TWP .

Installation instructions - Printer friendly (pdf)

Colored Wiring Diagrams used with the ADP-1101-10AS 

#6A7. Two 120Vac separate vent switches with Primary and Secondary fans, ADP-1102-TWP & ADP-1101-10AS, replacement air damper, Power Open 

#6A8. 
Two 120Vac separate vent switches with Primary and Secondary fans, ADP-1102-TWP &  ADP-1101-10AS, replacement air damper, Power Close 



ADP-1101-10AS - Interface Relay Adpator
 