| HMI Hoyme ADP- 0MV2 - S5A |
|
| Interlocking Relay Adaptor: for combustion fresh air inlet damper HOM - 24Vac; connects to 250 mVdc to 100 Vdc - 2 wire safety control system. Damper proves to be open before fire starts. C/W 2 relays, printed circuit & Test/Run switch. Also ideal for commercial use.
Installation Instructions - Printer friendly (pdf)
|
 |
| |
|
| HMI Hoyme ADP- 1102 - S5A |
|
| 120Vac Interlocking Relay Adaptor: for combustion fresh air inlet dampers and Flue Dampers using 120Vac safety control systems. Dampers prove to be open before fire starts. C/W 120Vac relay, 24Vac relay & Test/Run switch. Also ideal for commercial use.
Installation Instructions - Printer friendly (pdf)
|
 |
| |
|
| HMI Hoyme ADP- 1102 - TPX |
|
| 120Vac / 24Vac Interlocking Relay Adaptor Control Center: to control 24Vac ventilation fresh air inlet damper with end switch connected to 120Vac exhaust fan. Damper proves to be open before exhaust fan runs. Also turns on furnace circulation fan. C/W 2 relays: 120Vac and 24Vac. Contacts 10 Amps.
Installation Instructions - Printer friendly (pdf)
Colored Wiring Diagrams used with the ADP-1102-TPX
#11. Vent switch, combustion air, and interlocking replacement air
#12. Vent switch and interlocking replacement air
|
 |
| |
|
| HMI Hoyme TMADP- 1102 - TPX |
|
| Automatic Relay Adaptor Control Center: for ventilation fresh air, c/w 24Vac Interval Timer. Interconnects and turns on a 120Vac exhaust fan, furnace circulation fan and opens a 24Vacfresh air inlet damper simultaneously as per times designated. Responds also to the regular 120Vac manual ventilation switch. C/W 2 relays: 120Vac and 24Vac. Contacts 10 Amps.
Installation Instructions - Printer friendly (pdf)
Colored Wiring Diagrams used with theTMADP-1102-TPX
#9. Timer, vent switch, combustion air, and replacement air
#9A. Timer, vent switch and replacement air
#10. Timer, vent switch and replacement air opens during firing
|
 |
| |
|
| HMI Hoyme ADP- 1101 - 05A |
|
| Adaptor control centre combines 120Vac with 24Vac circuits. Interconnects the thermostat fan cycle, primary exhaust fan switch and the furnace circulating fan. Fresh air damper, if installed, also opens simultaneously with exhaust fan. Will not interfere with air conditioning controls. C/W 120Vac coil with 24Vac switching for 24Vac dampers and thermostat circuits.
Installation instructions - Printer friendly (pdf)
Colored Wiring Diagrams used with the ADP-1101-05A
#5. 120VAC vent switch, combustion air, and replacement air
#5A.120VAC vent switch, combustion air and replacement air(2 furnaces)
#5B.120VAC vent switch, combustion air(2 furnaces), replacement air
#6. 120VAC vent switch and replacement air opens during firing
|
 |
| |
|
| HMI Hoyme ADP- 0241- 05A / 10A |
|
| This Relay Adaptor may be used as an automatic switch having a 24Vac coil and 120Vac contact points to control a line voltage circuit for either a 5 or 10 amp draw. i.e. Exhaust Fan. Adaptor can also be used 100% for 24Vac switching (See ADP-1101). Switching 24Vac dampers and thermostat circuits use 5A type only and for 120Vac fan control, use 10A type only.
Installation instructions - Printer friendly (pdf)
Colored Wiring Diagrams used with the ADP-0241-05A
#7. 24VAC vent switch, combustion air, and replacement air
#8. 24VAC vent switch and replacement air opens during firing
|
 |
| |
|