120 Vac two double pole vent switches with two exhaust fans, combustion air and replacement air  

HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations. 
Wires of the Combustion Air Damper, however, are colored as shown



Diagram #5C: Forced Air Furnace having a combustion air and a replacement air supply duct together with two exhaust fans controlled by two separate Double Pole Ventilation Switches.
 
ADDED: 1. Combustion Air Damper (HOM-0x11-SF1); 2. Replacement Air Damper (HAC-0x10-OPC); 3. Two Ventilation Switches (DP) to supply controlled 120Vac;
 4. Relay Adaptor (ADP-1101-05A) which functions as a control centre.

OPERATION:
1. Combustion Air Damper and Replacement Air Damper open during furnace firing.  2. Either Ventilation Switch turns on Exhaust Fan, opens Replacement Air Damper and turns on Furnace Fan simultaneously. 3. Optional switch (i.e. toggle switch, timer, de-humidistat) provides full control of Replacement Air damper to open separately provided the damper is the Power Close  (PC) type.

N.B. Replacement Air Damper is not affected by the ‘Manual’ setting of the furnace fan.
 