Forced Air Furnace and a replacement air damper, Power Open

HMI Hoyme Manufacturing Inc. Special Note: Circuits are colored for clarification only and are not necessarily those found in actual installations.




 
Diagram #4A: Forced Air Furnace having a replacement air supply duct.
 
ADDED: Power Open Replacement Air Control Damper (HAC-0x10-OPO).
 
OPERATION: 1. Replacement air damper is interconnected to the furnace so that the damper opens to provide fresh air during the heating cycle and closes to conserve energy when the fire stops. Adjustment of the Heat Anticipator is required on a regular type thermostat. 2. The fresh air damper may be held open continuously by adding a Toggle Switch (SPDT) between wires from ‘W’ and ‘R’ of the furnace.
 
N.B. Replacement Air Damper is not affected by the ‘Manual’ setting of the furnace fan.
 
 
 